  model | GUD-1 | GUD-2 | Input Voltage | Single-Phase100/110V, 50/60Hz±10% | Single-Phase 200/220V, 50/60Hz±10% | Applied Motor Output | 6W-90W, AC SPEED CONTROL MOTOR | REAL RPM RATIO RPM | Red 7 Segment 4 Digit after red LED on Red 7 segment 4 Digit after green LED on | Applied Motor Current | 2.0A | Indication of LED | Power Supplied (STOP) = Green LED Running(RUN) = Red LED Case of Error = Red LED blinks Soft Up movement = Red, Soft Down movement = Red T.G selection = Red DATA LOCK = Red | Control Method | AC phase control method according to digital PID operation by Micom Sensor Type | Sensor Type | AG, TG(Tacho), contact switch, encoder 12~24 poles TG or 12~24 Pulse 1KHz per a revolution | Control Type | speed control in proportion to measurement value (PID operation automatic control by Micom) | Speed Volume Method | each 1.5, 10, 50, 100 increases, decreases depending on setting input | Control Extent | 50Hz=90~1400rpm, 60Hz=90~1700rpm | Control Extent | Micom magnetic diagnosis | Consuming Electricity | about 5W(10AV) Motor except for consuming electricity | Control Error | average± 0.5% | 4 Setting Keys | RUN/STOP, MODE, UP, DOWN | Measurement Method | pulse period operation measurement method by Micom | Remote RUN/STOP | Remote S/W | STOP/RUN | control type within 0~10sec | Inner Vibration Durability | 10~55Hz2, 0.7mm X, Y, Z directions 2 hours | Voltage in Insulation | sufficient to withstand 1500V at 50/60Hz applied between the electric terminal and the ground for over 1 min. | Inner Shock Durability | 250m/sec 6 directions 3 times | Inner Noise | electricity line 1500V/ms TG line 200V/ms | Controller Lifetime | Semi-permanent if ambient is most suitable | Insulation Resistance | between TG terminal and the ground for over 1 min. | DIMENSION | 60(W)×100(H)×103(D) | Ambient Temperature | -10℃+50℃ | Ambient Humidity | 85% Maximum (non-condensing) |   About 2 seconds of “RESET TIME” is required for the power supply. Digital indications are not carried out during these seconds. Please operate with keys after the power and the digital indications are on. | Automatic Change of Regular Frequency Powered on, it automatically chooses the use frequency by measuring the frequencies using MICOM, sets Max. 1700 rpm for 60Hz and 1400 rpm for 50Hz. |  Error Indication Error occurred, POWER/RUN/ERR Indicator LED twinkles with red color. (Refer to the instructions for more information about errors.) | - REAL RPM Indication LED=ON. RATIO RPM Indication LED=OFF. SOFT UP=OFF. SOFT DOWN=OFF - T.G Selection LED=OFF (24 pole). LOCK Function LED=OFF. RPM=90 - Basic Setting Input Method : On condition of turning the power on, press the buttons of "MODE" and "UP" for about 2 seconds, and the program mode has begun. - Special Setting Input Method : After pressing the buttons of "MODE" and "UP" with the factors related to the motor and the controller, turn the power on. And the special setting mode has begun. (Type of Menu: P.I.D.) After turning off the power, press the buttons of MODE and UP at the same time, inputting the power, and then wait for about 3 seconds. It is in the condition of program function setting. | (1) Decelerator Ratio Denominator of RPM indicated for free scale. If the decelerator is used, input the decelerator ratio for indicating actual rotations of the charged side (machine side). | (2) SOFT UP To set SOFT UP time, use ↑ and ↓ keys. Max. 30 sec. is selectable in units of 0.1 sec. 0↔30.0 sec. | (3) SOFT DOWN To set SOFT DOWN time, use ↑ and ↓ keys. Max. 30 sec. is selectable in units of 0.1 sec. 0↔30.0 sec. | |  When powered on, the operation setting is possible. (1) If it is "1" When powered on, the current operation is carried out before shutting off. Before shutting off | Powered on | “RUN” status | Drive (after 2 sec.) | “STOP” status | “STOP” | | (2) If it is "0" When powered on, the operation stops regardless of the status before shutting off. Use the RUN/STOP key to resume operation. Before shutting off | Powered on | “RUN” status | “STOP” | "STOP" status | “STOP” | | |        |