Speed Control Unit

Mã sản phẩm: S000128

- REAL RPM Indication LED=ON. RATIO RPM Indication LED=OFF. SOFT UP=OFF. SOFT DOWN=OFF - T.G Selection LED=OFF (24 pole). LOCK Function LED=OFF. RPM=90 - Basic Setting Input Method : On condition of turning the power on, press the buttons of "MODE" and "UP" for about 2 seconds, and the program mode has begun.

Giá: Liên hệ
MODEL GUD-1 GUD-2
Operation Voltage 100/110V 200/ 220/240V
Frequency 50 / 60Hz
   
 
 
 
 
 
  
 



 
model GUD-1 GUD-2
Input Voltage Single-Phase100/110V, 50/60Hz±10% Single-Phase 200/220V, 50/60Hz±10%
Applied Motor
Output
6W-90W, AC SPEED CONTROL MOTOR REAL RPM
RATIO RPM
Red 7 Segment 4 Digit after red LED on
Red 7 segment 4 Digit after green LED on
Applied Motor
Current
2.0A
Indication 
of LED
Power Supplied (STOP) = Green LED        Running(RUN) = Red LED
Case of Error = Red LED blinks                Soft Up movement = Red, Soft Down movement = Red
T.G selection = Red                                 DATA LOCK = Red
Control Method

AC phase control method according
to digital PID operation by Micom 
Sensor Type

Sensor Type AG, TG(Tacho), 
contact switch, encoder

12~24 poles TG or 
12~24 Pulse 1KHz 
per a revolution
Control Type speed control in proportion to
measurement value 
(PID operation automatic control by
Micom)
Speed Volume
Method
each 1.5, 10, 50, 100 increases, 
decreases depending on setting input
Control Extent 50Hz=90~1400rpm, 60Hz=90~1700rpm
Control Extent Micom magnetic diagnosis Consuming
Electricity
about 5W(10AV) Motor 
except for consuming electricity
Control Error average± 0.5% 4 Setting Keys RUN/STOP, MODE, UP, DOWN
Measurement Method pulse period operation 
measurement method by Micom
Remote 
RUN/STOP
Remote S/W
STOP/RUN control type within 0~10sec Inner Vibration
Durability
10~55Hz2, 0.7mm X, Y, Z directions 2 hours
Voltage in
Insulation
sufficient to withstand 1500V at 
50/60Hz applied between the electric
terminal and the ground for over 1 min.
Inner Shock Durability 250m/sec 6 directions 3 times
Inner Noise electricity line 1500V/ms
TG line 200V/ms
Controller Lifetime Semi-permanent 
if ambient is most suitable
Insulation
Resistance
between TG terminal and the
ground for over 1 min.
DIMENSION 60(W)×100(H)×103(D)
Ambient
Temperature
-10℃+50℃ Ambient Humidity 85% Maximum 
(non-condensing)


 

  

 

 
About 2 seconds of “RESET TIME” is required for the power supply. Digital indications are not carried out during these seconds.
Please operate with keys after the power and the digital indications are on.

 
Automatic Change of Regular Frequency
Powered on, it automatically chooses the use frequency by measuring the frequencies using MICOM, sets Max. 1700 rpm for 60Hz and 1400 rpm for 50Hz.


Error Indication
Error occurred, POWER/RUN/ERR Indicator LED twinkles with red color.
(Refer to the instructions for more information about errors.)

 

- REAL RPM Indication LED=ON. RATIO RPM Indication LED=OFF. SOFT UP=OFF. SOFT DOWN=OFF
- T.G Selection LED=OFF (24 pole). LOCK Function LED=OFF. RPM=90
- Basic Setting Input Method : On condition of turning the power on, press the buttons of "MODE" and "UP"
for about 2 seconds, and the program mode has begun.
- Special Setting Input Method : After pressing the buttons of "MODE" and "UP" with the factors related to 
the motor and the controller, turn the power on. And the special setting mode has begun.
(Type of Menu: P.I.D.) After turning off the power, press the buttons of MODE and UP at the same time,
inputting the power, and then wait for about 3 seconds. 
It is in the condition of program function setting.


 
(1) Decelerator Ratio
Denominator of RPM indicated for free scale. If the decelerator is used, input the decelerator ratio for indicating actual rotations of the charged side (machine side).
(2) SOFT UP
To set SOFT UP time, use ↑ and ↓ keys. Max. 30 sec. is selectable in units of 0.1 sec. 0↔30.0 sec.
(3) SOFT DOWN
To set SOFT DOWN time, use ↑ and ↓ keys. Max. 30 sec. is selectable in units of 0.1 sec. 0↔30.0 sec.

When powered on, the operation setting is possible.

(1) If it is "1" 

When powered on, the current operation is carried out before shutting off.

Before shutting off Powered on
“RUN” status Drive (after 2 sec.)
“STOP” status “STOP”

 

(2) If it is "0" 
When powered on, the operation stops regardless of the status before shutting off. Use the RUN/STOP key
to resume operation.
Before shutting off Powered on
“RUN” status “STOP”
"STOP" status “STOP”


 


 
 

 

 


 


 


Sản phẩm này không có hình ảnh khác
Số ký tự được gõ là 250

Sản phẩm cùng loại

 
      

Trang chủ        |     Giới thiệu        |       Sản phẩm       |        Tin tức - Sự kiện       |       Tuyển dụng     |     Download      |      Liên hệ

 
I-motion Vietnam CO., Ltd
Add: 90/2 Phan HUy Ich st, Ward 14, Go Vap Dist, Ho Chi Minh City, VN
Phone: 08.39470421 Fax: 08.3947 0454
Email: lhk@imotionasia.com.vn
Website:
www.imotionasia.com.vn
I-motion Pte Ltd
Add: Blk 3026, #02-148 Ubi Road 1 Singapore 40879
Tel: +65-6841 7877
Fax: +65-62803655

Cửa lưới chống muỗi | giàn phơi thông minh | khung bảo vệ cửa sổ | lưới an toàn ban công gian phoi cua luoi